Crown MA-5000i
 - Amplifiers
 - Audio
 - Audiolines.com
Employment
Links
Crown MA-5000i
 - Amplifiers
 - Audio
 - Audiolines.com

       Home Terms & Conditions
   Contact Us     About Our Store   

        Recover password    FAQ





 

 Categories 
  Audio

  Lighting

  Package Deals

  Staging

  Rental

  Blowouts/Closeouts

 


 Manufacturers 
 

 Other Resources 
Manufacturer Rebates
Banners & Images
 
 
Buy Gift Certificates
Gift Certificate Recovery
 


 Help 
  Recover password
  Contact Us
  Privacy statement
-  Terms & Conditions


 


We ship Worldwide
shipping methods UPS & Fedex

We accept
all forms of payment

Preferred Payment Methods

Apple Authorized Dealer
 

Crown MA-5000i #22464

 

Crown MA-5000i

 

Options
 
Quantity


 Add to cart 
        

New Price: $4,255.00

We will beat any price.
Seen a better price or want to make us an offer? Click Here.


Link to this product.

Details


Features

  • The i Series continues the Macro-Tech legacy of unparalleled sonic accuracy and detail, putting sound quality above all else
  • Patented, cutting-edge Class-I circuitry gets more power out of an amplifier with less waste
  • Rugged construction ensures that all Macro-Techs are built to withstand years of abuse on the road
  • Global Power Supply - designed to deliver maximum power no matter where your schedule takes you
  • Studio-quality analog signal processing with built-in load, line voltage, input and output monitoring
  • Standard Ethernet networking via System Architect provides integratedmonitoring and control to give system operators access to the system from anylocation

Power Output (Guaranteed minimum power in watts at 20Hz-20kHz with 0.35% THD)

  • 2 ohm dual (per ch), 20 mS BURST: 2,565W
  • 2 ohm dual (per ch), 20Hz-20kHz: 1,800W
  • 2 ohm dual (per ch), 1kHz: 1,800W
  • 4 ohm dual (per ch): 2,000W
  • 8 ohm dual (per ch): 1,250W
  • 4 ohm bridge: 3,600W
  • 8 ohm bridge: 4,000W

Performance

  • Frequency Response (at 1 watt, 20 Hz - 20 kHz into 8 ohms): �0.25 dB.
  • Signal to Noise Ratio below rated full-bandwidth power, A-weighted: > 108 dB.
  • Total Harmonic Distortion (THD) at 1 watt into 8 ohms: < 0.1%.
  • Total Harmonic Distortion (THD) Plus Noise at full rated power: < 0.35%, 20 Hz to 20 kHz.
  • Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1, from full rated output to �30 dB: < 0.35%.
  • Damping Factor (20 Hz to 100 Hz at 8 ohms): > 5000.
  • Crosstalk (below rated power, 20 Hz to 1 kHz): > 80 dB.
  • Common Mode Rejection (CMR) (20 Hz to 1 kHz): 55 dB, typically >70 dB.
  • DC Output Offset (shorted input): < � 3 mV.
  • Input Impedance (nominal): 10 kilohms balanced, 5 kilohms unbalanced.
  • Maximum Input Level: +20 dBu typical.
  • Network: Onboard TCP/IQ and HiQnet, compatible with standard 100 Mb Ethercom hardware.
  • Load Impedance: (Note: Safe with all types of loads) Stereo: 1/2/4/8/16 ohms. Bridge Mono: 2/4/8 ohms.
  • Input Sensitivity (referenced to 8 ohm rated output): 1.4V, 32 dB gain, and 26 dB gain.
  • Voltage Gain (referenced to 8 ohm rated output): 37.1 dB to 22.2 dB
  • Required AC Mains: Universal AC input, 100-240VAC, 50/60 Hz (�15%). Maximum AC mains voltage 264VAC.
  • AC Line Connector: Five cordsets supplied with amplifi er (USA, UK,European, Australia, India).

Front Panel Controls and Indicators

  • Bridge Mode Indicator: Amber LED illuminates when the amplifi er is set to Bridge-Mono mode.
  • Ready Indicator: Red LED, one per channel. Bright red: Channel is ready to pass audio. Red: Onset of compression (thermal event or fan failure). Off: Thermal event has occurred.
  • Signal Indicators: One green LED per channel. Solid green: Input signal is above �40 dBu. Bright green: Channel�s output signal has reached the onset of audible clipping.
  • Power Indicator: Blue LED indicates amplifier has been turned on and AC power is available. The LED will fl ash when the AC line voltage is 10% above or below the nominal rated value.
  • Data Indicator: Yellow LED on front panel indicates network data activity. Data indicator flashes only when the amplifier is polled for data, or is polled to see whether it is online
  • Power Switch: Push-on/push-off switch with built-in green AC mains present indicator.
  • Volume Control: Precision detented attenuator with 31 steps, press-and-hold mute function.
  • Volume Control LED Ring: A ring of green LEDs around each volume controlshow the position of the control. Entire ring flashes when channel is muted.Can be converted to be a level meter.

Back Panel Controls, Indicators and Connectors

  • Power Cord Connector: Locking, detachable 20 amp IEC inlet. Voltage range is indicated above IEC inlet.
  • Reset Switch/Circuit Breaker: If the current draw of the amplifier exceeds safe limits, this breaker automatically disconnects the power supply from the AC mains. The switch resets the circuit breaker.
  • Output Connectors: Two high-current, 50A Neutrik� Speakon� NL4MLP (mates with NL4FC or NL4), one per channel. Ch 1 Speakon� is wired with Ch 1 and Ch 2 outputs for use with single 4-conductor cable. Two pairs of high-current, 60A color-coded 5-way binding posts (for banana plugs, spade lugs or bare wire).
  • Analog Input Connectors: A 3-pin female XLR connector for each channel.
  • Analog Loop Thru Connectors: Two male XLR passive analog loop through.
  • Mode Switch/Indicator: Sets amplifi er to Stereo, Bridge, or Input Y mode. OFF=Stereo, YEL=Bridge, GRN=Y.
  • Network Connector: This Neutrik� Ethercon connector accepts an RJ-45 connector for TCP/IQ or HiQnet networking. Next to the connector is a yellow LINK ACT indicator that shows network activity, and a green 100Mb indicator that shows a 100Mb network connection.
  • Data Indicator: Yellow LED on back panel indicates network data activity. Data indicator flashes only when the amplifi er is polled for data, or is polled to see whether it is online.
  • Preset Indicator: Yellow LED flashes to signal the number of the current preset if active.
  • Input Sensitivity Switch: Three-position switch providing 1.4V, 32 dB, and26 dB settings for both channels.

Firmware/Software

  • Firmware can be updated at www.crownaudio.com > Support > Downloads.
  • Software features: Same as PIP-Lite module (except no Listen Bus): UserPresets, Clip Event Monitor, Input Signal Level Monitor, Output Signal LevelMonitor, Thermal Headroom Level Monitor, Power/Standby Control, Signal Mute,Polarity Inverter, Input Signal Fader, Dynamic Gain Monitors (Ghost Faders),Amplifier Information, User and Channel Labels, Amplifier Mode, AmplifierOutput Mode, Line Voltage Monitor, Error Reporting, Auto Standby, Input SignalCompressor/Limiter, Peak Voltage Limiter, Average Power Limiter, ClipEliminator, Thermal Limiter, Limiter Tie, Load Supervision.

Construction

  • Cooling: Dual-zone, microprocessor controlled, continuously variable speed fans, front-to-back airflow.
  • Front Panel: Cast aluminum with integrated handles.
  • Dimensions (W x H x D): 19 x 3.5 x 16.2
  • Weight: 28 lbs net, 36 lbs shipping
  • Protection: Amplifi er is protected against reactive loads, faults and shorts. If one channel experiences a catastrophic failure, the entire amplifier will shut down.
  • Included Accessories: Rear rack ears, rack screws, operation manual, powercords, foam air filter.

 

 

 

 Search 
      
Advanced search    
 


 Your cart 
Cart is empty
  View cart
  Checkout
 


 Authentication 
Username or Email Address

Password

            Log in
            Register

Get Weekly Savings
In Your Email
Email:

 



 News 
Audiolines.com is now proud to be an authorized Digidesign Protools HD (stocking) Dealer


Free Clinic on M-Audio May 14, 6PM



 


Copyright © 2002-2008 Audiolines.com  
Powered by Audiolines.com